7 installation, Operating environment, Ambient temperature – IDEC High Performance Series User Manual

Page 1370: Hg2f installation, Installation -54, Caution

Advertising
background image

4 HG2F

34-54

WindO/I-NV2 User’s Manual

4.7 Installation

Operating Environment

For designed performance and safety of the HG2F, do not install the HG2F in the following environments:

• Where dust, briny air, or iron particles exist.
• Where oil or chemical splashes for a long time.
• Where oil mist is filled.
• Where direct sunlight falls on the HG2F.
• Where strong ultraviolet rays fall on the HG2F.
• Where corrosive or combustible gasses exist.
• Where the HG2F is subjected to shocks or vibrations.
• Where condensation occurs due to rapid temperature change.
• Where high-voltage or arc-generating equipment (electromagnetic contactors or circuit protectors) exists in the

vicinity.

Ambient Temperature

• Allow sufficient space for ventilation, and install the equipment away from heat sources.
• Allow at least 100mm between the HG2F and walls or other equipment.
• Do not install the HG2F where the ambient temperature exceeds the rated operating ambient temperature range.

When mounting the HG2F in such locations, provide a forced air-cooling fan or air-conditioner to keep the ambient
temperature within the rated temperature range.

• The HG2F is designed to install on a vertical plane so that natural air-cooling is provided. If you install it using any

other orientation, use forced-air cooling, or lower the ambient operating temperature.

HG2F Installation

• Make a panel cut-out on the panel with the dimensions shown below.

• Place the HG2F in a panel cut-out and fasten with the attached mounting clips at four places to a torque of 0.15 to

0.2 N•m uniformly.

CAUTION

• Do not tighten excessively, otherwise the HG2F may warp and cause wrinkle on the display, or

impair the waterproof characteristics.

• If the mounting clips are tightened obliquely to the panel, the HG2F may fall off the panel.
• When installing the HG2F into a panel cut-out, make sure that the gasket is not twisted. Especially

when re-installing, take special care because any twists in the gasket will impair the waterproof
characteristics.

B

A

Unit: mm

A

B

Panel Cut-out

126.5

+0.5
0

162.5

+0.5
0

1.6 to 5.0

Panel

Mounting

Clip

HG2F

Advertising