NETGEAR M4350-24F4V 24-Port 10G SFP+ Managed AV Network Switch User Manual

Page 117

Advertising
background image

Configure and display detailed green
Ethernet settings for an interface

You can select a single interface and configure and display detailed green Ethernet
settings.

To configure and display detailed green Ethernet settings for a single interface:

1. Launch a web browser.

2. In the address field of your web browser, enter the IP address of the switch.

If you do not know the IP address of the switch, see Log in to the main UI with a web
browser
on page 27 and the subsections.

The login page displays.

3. Click the Main UI Login button.

The main UI login page displays in a new tab.

4. Enter admin as the user name, enter your local device password, and click the Login

button.

The first time that you log in, no password is required. However, you then must
specify a local device password to use each subsequent time that you log in.

The System Information page displays.

5. Select System > Management > Green Ethernet > Green Ethernet Details.

The Green Ethernet Details page displays.

6. From the Interface menu, select the interface.

7. From the Energy Detect Admin Mode menu, select to enable or disable this mode.

By default, this mode is disabled for the interface. When a port link is idle, the
underlying physical layer goes into low power idle for a short period of time, and
then checks for port link pulses again so that auto-negotiation remains possible. In
this way, the switch saves power when no link partner is present for the port.

8. From the EEE Admin Mode menu, select to enable or disable this mode.

With Energy Efficient Ethernet (EEE) mode enabled, the port transitions to low power
mode during a link idle condition. The default value is Disabled.

9. In the EEE Transmit Idle Time field, enter the period that the interface must remain

idle (without receiving packets for transmission) before entering the low-power idle
(LPI) state.

The range is from 600 to 4294967295 seconds. The default is 600 seconds.

10. In the EEE Transmit Wake Time field, enter the period that the interface remains in

the LPI state before returning to the active state after it receives a packet for
transmission.

Main User Manual

117

Configure Switch System
Information

Fully Managed Switches M4350 Series Main User Manual

Advertising