Leprecon LP-1600 Series User Manual

Page 8

Advertising
background image

8

7. RS-232

Standard Models only:

P C Connection

Pin

Description

DB-9 DB-25

2

Data into LP-1600 3 2

3

Data out of LP-1600 2 3

5

Ground

5 7



8. DMX Out

Industry Standard DMX Connection:

Pin

Description

1

Common

2

Data 1-

3

Data 1+

4

Data 2-

5

Data 2+


9. Reset

Recessed system reset switch.

10. MIDI Out

Industry standard MIDI output connection.

11. MIDI In

Industry standard MIDI input connection.

12. Audio Gain

Rotate clockwise to increase audio input sensitivity.

13. Audio In

Standard ¼” phono plug.

2.1. Power requirements

The LP-1600 console is powered from a separate AC input power supply. The
power supply includes an IEC type power cord, such as is used with Personal
Computer power supplies. The LP-1600 power supply requires less than two
amps of input power.

The power supply furnished with the LP-1600 will operate with voltages from
90 to 240 volts, with a frequency of 50 or 60 HZ. This supply should be
acceptable for standard voltages anywhere in the world.

Because temporary power distribution is usually set up for portable lighting
systems, it is possible to accidentally connect the console to a higher line
voltage, or to a source where two of the three line wires (for example, the hot
wire and the ground wire) have been swapped. Some protection from such
accidents has been designed into the LP-1600, but serious damage to the
board and operator can still result from incorrect power connections. It is

Advertising