Advertising
background image

Memo :

0

Use the user button assigned with “Full Auto” to

enter the Full Auto mode also activates the

Automatic White Balance mode. In this case, the

Iris, Gain and Shutter also enter into Auto mode

forcibly.

0

The white balance operation during Full Auto

mode can be configured in [Camera Function]

B

[Full Auto]

B

[White Balance].

0

When [Camera Function]

B

[User Switch Set]

B

[AE Lock] is set to “AE/FAW” or “FAW”, the white

balance when the user button that is assigned

with [AE Lock] is pressed can be fixed while in

the Automatic White Balance mode.

(

A

P113 [ AE Lock ] )

0

If [White Balance] is assigned to the user button,

pressing the assigned user button will display

the FAW Paint Adjustment screen.

(

A

P45 [Assignment of Functions to User

Buttons] )

FAW Paint Adjustment
You can fine-adjust the white balance that was

automatically adjusted.

1

Select [Camera Process]

B

[White

Balance]

B

[FAW Paint] and press the Set

button (

R

).

The FAW Paint Adjustment screen appears.

.

1

FAW Paint

White Balance

2

Adjust the R and B values.

Use the cross-shaped button (

JK

) to adjust R

value and (

HI

) to adjust B value.

.

B

R

3

Press the Set button (

R

).

Returns to the [White Balance] screen.

.

B Value

R Value

FAW Paint

White Balance

Manual White Balance Mode (Manual

Switching)

1

Set Full Auto mode to off using the user

button assigned with “Full Auto”.

0

Use the [WHT.BAL] switch to select “PRST”

(preset mode), “A” (memory A mode), or “B”

(memory B mode).

Memo :

0

You can set the Full Auto White Balance feature

to either [A], [B], or [PRST] in [Camera

Function]

B

[FAW].

(

A

P110 [ FAW ] )

0

The FAW (Full Time Auto White Balance) mode

makes automatic adjustments by sampling the

color temperature of the video to obtain the most

appropriate white balance level.

Preset Mode (PRST)

0

Two different color temperature settings are

registered on this camera recorder. You can

switch between them by pushing the [AWB/

USER8] switch upward or using the user button

assigned with “AWB”.

Default setting:

[Preset Temp.]

: 3200K

[Alternative Temp.] : 5600K

1

Set the [WHT.BAL] switch to “PRST”.

2

Push the [AWB/USER8] switch upward or

press the user button assigned with the

“AWB” function.

0

The color temperature switches.

(“Preset Temp.”

1

“Alternative Temp.”)

64

Adjusting the White Balance

Sh

ooting

Advertising