3 the lenze variables browser, 1 browsing for variable definitions, The lenze variables browser – Lenze PC-based Automation Industrial PC User Manual

Page 111

Advertising
background image

2.5 EN - 01/2012

L

111

Industrial PC | Parameter setting & configuration

Visualisation with »VisiWinNET®«

Constellation and connection

13.3.3

The Lenze Variables Browser

The variables browser can be used to browse for variables on the devices connected to the

Industrial PC and to transfer them to a »VisiWinNET®« project. For this purpose, a

connection between the integrated »VisiWinNET®« development environment and the IPC

is not required. The data is read from the locally available parameter files, which have been

exported from the »Engineer« in advance.

How to call up the Variables Browser:

1. Open the Project Explorer (



Open the Project Explorer

).

2. Open the Variables ->Channels branch in the Project Explorer.
3. Select Browse variables in the context menu of the intended communication

channel.

• The Lenze Variables Browser window appears. In the Devices selection list all

devices available for reading variable definitions appear.

13.3.3.1

Browsing for variable definitions
When you have started the Lenze Variables Browser, you can select one or more devices

and then read their variable definitions.