1 centralised control system, 2 ipc data manager, Ipc data manager – Lenze PC-based Automation Industrial PC User Manual

Page 37: Industrial pc | parameter setting & configuration

Advertising
background image

2.5 EN - 01/2012

L

37

Industrial PC | Parameter setting & configuration

System structure

Industrial PC

5.2.1

Centralised control system

The PLC of the Industrial PC (Logic/Motion) is the central control component, consisting

of the PLC runtime program with the running PLC application.
– Via the data manager and the fieldbus driver the PLC (Logic/Motion) has access to

the system components and field devices.

[5-1]

* The PROFIBUS fieldbus driver can only be accessed via PLC (Logic/Motion). Access via Engineer, GDC or VisiWinNET®

Runtime is not provided.

Field devices and the Industrial PC compose the machine to be commissioned by the

Engineering PC.

The Industrial PC can read parameters from and write parameters to the connected

field devices via the fieldbus (Logic/Motion).

5.2.2

IPC data manager

With the Data manager, Lenze Industrial PCs contain a central tool for the configuration

and data management of a system.

A system in this connection is the combination of an Industrial PC and the field devices

connected to it and registered via the fieldbus.

Advertising