Industrial PC | Parameter setting & configuration

Visualisation with »VisiWinNET®«

Lenze specifications - exception handling

124

L

2.5 EN - 01/2012

13.5

Lenze specifications - exception handling

13.5.1

Install additional fonts

How to install additional fonts for visualisation:

1. Copy the additional font file to the \Storage\Fonts directory on the CF card.
2. In the PostStart.txt file, add the AddFont.exe entry.

The PostStart.txt file is in the \Storage directory (basic directory of the CF

card).

13.5.2

No access to variables with AT declaration possible (CoDeSys direct driver)

If a variable in the PLC is to be directly assigned to a certain address, the corresponding

variable »PLC Designer« variable is declared with the AT keyword (example:

xSchalterHeizung7 AT %QX0.0: BOOL;).

Note!

The access to variables with AT declaration is not supported by the CoDeSys

direct driver.
• Variable contents may be displayed incorrectly.
• Write accesses may cause incorrect data contents.