Industrial pc | parameter setting & configuration, Interface parameters of the card in slot 2 – Lenze PC-based Automation Industrial PC User Manual

Page 212

Advertising
background image

Industrial PC | Parameter setting & configuration

Parameter reference

Industrial PC extension modules

212

L

2.5 EN - 01/2012

Interface parameters of the card in slot 2

C1578

C1580

C1581

C1582

C1583

C1584

C1586

Parameter | Name:

C1578 | Apply IP configuration

Data type: UNSIGNED_16

Index: 22997

d

= 59D5

h

Code for activating the set configuration. The interface is activated by writing a "1".
Selection list

(Lenze setting printed in bold)

Information

1 Activate device
0 No command

;

Read access ; Write access … CINH … PLC STOP ; No transfer

Parameter | Name:

C1580 | Dhcp

Data type: UNSIGNED_32

Index: 22995

d

= 59D3

h

Activation of the configuration. DHCP states:

• "0" = Inactive

• "1" = Active

If DHCP is active, the codes 21-25 do not have any function
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 1

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1581 | IP address

Data type: VISIBLE_STRING

Index: 22994

d

= 59D2

h

IP address of the card

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1582 | Subnet mask

Data type: VISIBLE_STRING

Index: 22993

d

= 59D1

h

Subnet mask of the card

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1583 | Default gateway

Data type: VISIBLE_STRING

Index: 22992

d

= 59D0

h

Default gateway of the card

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1584 | Domain

Data type: VISIBLE_STRING

Index: 22991

d

= 59CF

h

Domain name of the card

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1586 | MAC address

Data type: VISIBLE_STRING

Index: 22989

d

= 59CD

h

MAC address (6 8-bit hexadecimal numbers) (e.g. 00:af:13:42:01:a8)

;

Read access … Write access … CINH … PLC STOP … No transfer