Industrial PC | Parameter setting & configuration

Parameter reference

Industrial PC extension modules

174

L

2.5 EN - 01/2012

C1080/4

C1081/1

C1081/2

Parameter | Name:

C1080/4 | ECAT bus scan result

Data type: UNSIGNED_8

Index: 23495.4

d

=

0x5BC7.0x04

h

Brief information on whether the master configuration complies with the physical bus structure or not. The stack

compares the master configuration with the actual bus structure.
Selection list

(Lenze setting printed in bold)

Information

0 No compliance

Master configuration does not comply with bus

structure

1 OK

Master configuration complies with bus structure

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1081/1 | ECAT state: State change

Data type: UNSIGNED_32

Index: 23494.1

d

=

0x5BC6.0x01

h

Change into master state via this code

Note: This parameter should only be set to examine start-up problems (e.g. master/bus does not reach the

'Operational' state). Setting this parameters only sets the state of the master stack. All other nodes remain in their

current states. Changing into the master state via this code may cause unstable system states.

• The bus state can never be higher than initiated by PLC.

• A new loading process of the master configuration cannot be initiated.

• Normally, loading the PLC program will stop the bus and bring it to 'Pre-Operational' state. If this fails, the bus

remains in either 'Unknown' or 'Initialisation' state.

• Normally, starting the PLC program will bring the bus to 'Operational' state. If this fails, the bus remains in either

'Pre-Operational' or 'Safe Operational' state.

Selection list

(Lenze setting printed in bold)

0 No action
1 Init
2 Pre-Operational
4 Safe Operational
8 Operational

;

Read access ; Write access … CINH … PLC STOP ; No transfer

Parameter | Name:

C1081/2 | ECAT master: State

Data type: UNSIGNED_8

Index: 23494.2

d

=

0x5BC6.0x02

h

Display of the current state of the master
Selection list

(read only)

0 Unknown
1 Init
2 Pre-Operational
3 Bootstrap mode

The Bootstrap mode is not supported

4 Safe Operational
8 Operational

;

Read access … Write access … CINH … PLC STOP … No transfer