2 setting ip addresses, Setting ip addresses – Lenze PC-based Automation Industrial PC User Manual

Page 45

Advertising
background image

2.5 EN - 01/2012

L

45

Industrial PC | Parameter setting & configuration

Web-based parameterisation with »WebConfig«

Requirements for working with the web-based parameterisation

The parameter lists can be found in the chapter entitled:



Parameter reference

( 125)

7.2

Requirements for working with the web-based parameterisation

This chapter provides you with information on how to prepare a remote connection for the

web-based parameterisation.

7.2.1

Online connection between the Engineering PC and Industrial PC

Connect the Engineering PC directly to the Industrial PC using a network cable.

or

Connect the Industrial PC to the network to which the Engineering PC has access.

7.2.2

Setting IP addresses

Setting for the direct connection between the Engineering PC and Industrial PC:

How to set the static IP address of the Engineering PC:

1. Open the Network connections dialog box Network connections.

(StartSettingsNetwork connections)

2. Select the network interface the Industrial PC is connected to.

Right-click Properties.

3. Select Internet protocol (TCP/IP).
4. Click the Properties button.
5. Select the Alternative configuration tab.

Note!

In the case of a direct connection between the Engineering PC and the Industrial

PC, a crossed network cable is required.
The settings of the static IP address of the Engineering PC are only to be carried

out for the direct connection between the Engineering PC and Industrial PC.

Note!

Recommended setting for the Engineering PC:
IP address: <192.168.5.100>
Default setting of the Industrial PC:
IP address: <192.168.5.99>, subnetwork <255.255.255.0>.