Industrial PC | Parameter setting & configuration

Parameter reference

Industrial PC extension modules

176

L

2.5 EN - 01/2012

C1081/6

Value is bit-coded:

Bit 0 Master ok
Bit 1 Reserved 1
Bit 2 Reserved 2
Bit 3 Reserved 3
Bit 4 Init
Bit 5 Pre-Operational
Bit 6 Safe Operational
Bit 7 Operational
Bit 8 Slaves in requested state
Bit 9 Master in requested state

Bit 10 Bus scan result
Bit 11 Reserved 4
Bit 12 DC: Activated
Bit 13 DC: Sychronised
Bit 14 DC: Busy
Bit 15 Reserved 5
Bit 16 Link up
Bit 17 Reserved 6
Bit 18 Reserved 7
Bit 19 Reserved 8
Bit 20 Reserved 9
Bit 21 Reserved 10
Bit 22 Reserved 11
Bit 23 Reserved 12
Bit 24 Reserved 13
Bit 25 Reserved 14
Bit 26 Reserved 15
Bit 27 Reserved 16
Bit 28 Reserved 17
Bit 29 Reserved 18
Bit 30 Reserved 19
Bit 31 Reserved 20

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1081/5 | ECAT master: State information

Data type: UNSIGNED_32

Index: 23494.5

d

=

0x5BC6.0x05

h

Parameter | Name:

C1081/6 | ECAT bus scan

Data type: UNSIGNED_8

Index: 23494.6

d

=

0x5BC6.0x06

h

Activation of the bus scan

The bus scan updates all EtherCAT codes.
Selection list

(Lenze setting printed in bold)

0 No action
1 The bus is scanned

;

Read access ; Write access … CINH … PLC STOP ; No transfer