Industrial pc | parameter setting & configuration, Interface parameters of the card in slot 2 – Lenze PC-based Automation Industrial PC User Manual

Page 190

Advertising
background image

Industrial PC | Parameter setting & configuration

Parameter reference

Industrial PC extension modules

190

L

2.5 EN - 01/2012

C1534

C1535

C1536

C1537

C1538

Interface parameters of the card in slot 2

C1574

C1580/1

C1580/2

Parameter | Name:

C1534 | Device: Software version

Data type: VISIBLE_STRING

Index: 23041

d

= 5A01

h

Software version of the card

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1535 | Device: Hardware version

Data type: VISIBLE_STRING

Index: 23040

d

= 5A00

h

Hardware version of the card

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1536 | Device: Serial number

Data type: VISIBLE_STRING

Index: 23039

d

= 59FF

h

Serial number of the card

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1537 | Device: Manufacturer

Data type: VISIBLE_STRING

Index: 23038

d

= 59FE

h

Manufacturer of the card

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1538 | Device: Manufacturing date

Data type: VISIBLE_STRING

Index: 23037

d

= 59FD

h

Manufacturing date of the card

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1574 | ECAT: MAC address

Data type: VISIBLE_STRING

Index: 23001

d

= 59D9

h

MAC address of the interface

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1580/1 | ECAT master config.: Date

Data type: DATE

Index: 22995.1

d

=

0x59D3.0x01

h

Date of the master configuration file in the file system of the IPC

The data manager refers to the ...\storage\IPC\PLC directory for the date of the master configuration file. If this file

is not available, the date will be displayed as "01.01.1900".

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1580/2 | ECAT master config.: Checksum

Data type: UNSIGNED_32

Index: 22995.2

d

=

0x59D3.0x02

h

Checksum of the master configuration file in the file system of the IPC

The data manager refers to the master configuration file in the ...\storage\IPC\PLC directory for the checksum. If this

file is not available, the value will be displayed as "0x00000000".

;

Read access … Write access … CINH … PLC STOP … No transfer