Industrial PC | Parameter setting & configuration

IPC backup & restore

Function

The log messages are named from M1 to M7. The following log messages can occur:

Tip!
The online help provides detailed information on

Windows® XP »IPC Backup & Restore«.

A backup covers the following data:

Operating system file and bootloader

Lenze software

System configuration

Data of the software

For the management of the backups created, an »IPC Backup & Restore« version for

Windows® XP is available. This version enables you to store the contents of the USB stick

or CF card on any hard disk. »IPC Backup & Restore« for Windows® XP is described in a

separate document.
The backup, restore and software update processes are identical. For procedure details

please refer to the specified chapters.

Message

Message in the logbook

Remedy

M1

System version is identical to the

selected update packet. No action

necessary.

The version of the Industrial PC is identical to that of the

update.

• Remove the USB stick or

• Change the control file of the USB stick with

»IPC Backup & Restore« under Windows® XP.

M2

Backup finished with <<1>> errors.

During the creation of Backup_orig, errors have occurred.

The update process cannot be continued.

• You can continue using the existing system, or you can try

again.

M3

Migration finished successfully.

Update finished with <<1>> errors.

Insert a backup CF card and restore

old system.

The migration of the databases has been carried out

successfully, but the installation of the update has failed.

Try the following:

• Establish an existing archive on your Compact Flash card.

• Then you can restore Backup_orig from the USB stick to

receive the original state.

M4

Update finished successful

The installation of the SW update has been completely

carried out successfully.

M5

Migration failed. Rollback finished

successful. The system was not

changed. Try Update again.

The migration of the databases has failed. The attempt to

effect a change was carried out in the temporary directory,

so that the Industrial PC was not changed.

• Repeat the update process.

M6

Migration failed. Restore was

successful. The system was not

changed. Try Update again.

The migration of the databases has failed. Afterwards

Backup_orig was restored successfully. Therefore the

original system is available again.

• Repeat the update process.

M7

Migration failed

Restore finished with <<1>> errors.

Insert a backup CF card and restore

old system.

The migration of the databases has failed. Backup_orig could

not be restored either.

Try the following:

• Establish an existing archive on your Compact Flash card.

• Then you can restore Backup_orig from the USB stick to

receive the original state.