Industrial PC | Parameter setting & configuration

Parameter reference

Parameters of standard devices

148

L

2.5 EN - 01/2012

C0168

C0169

C0170

C0171

C0172

C0173

Parameter | Name:

C0168 | FTP: Home user 10

Data type: VISIBLE_STRING

Index: 24407

d

= 5F57

h

Home directory of the user

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C0169 | WinCE-User: User 10 with telnet permissions

Data type: UNSIGNED_8

Index: 24406

d

= 5F56

h

User may use telnet
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C0170 | WinCE-User: User 10 with RAS permissions

Data type: UNSIGNED_8

Index: 24405

d

= 5F55

h

User may use RAS
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C0171 | FTP: Use authentication

Data type: UNSIGNED_32

Index: 24404

d

= 5F54

h

The FTP user has to identify himself/herself with name and password to establish a connection.

• Entering "1" activates the log-in procedure

• Entering "0" deactivates the log-in procedure
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 1

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C0172 | FTP: Allow anonymous

Data type: UNSIGNED_32

Index: 24403

d

= 5F53

h

An unregistered users is allowed to log in. The user name is "anonymous"

• Entering "1" activates the log-in procedure

• Entering "0" deactivates the log-in procedure
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C0173 | FTP: Allow anonymous upload

Data type: UNSIGNED_32

Index: 24402

d

= 5F52

h

An anonymous user is allowed to upload data to the IPC with the following code setting:

• FtpAllowAnonymousUpload = true and

• FtpAllowAnonymous = true.
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 1

;

Read access ; Write access … CINH … PLC STOP … No transfer