Industrial PC | Parameter setting & configuration

Parameter reference

Industrial PC extension modules

184

L

2.5 EN - 01/2012

C1096/17

C1096/18

Selection list

(read only)

0 Unknown
1 Init
2 Pre-Operational
4 Safe Operational
8 Operational

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1096/16 | ECAT: Current state

Data type: UNSIGNED_32

Index: 23479.16

d

=

0x5BB7.0x10

h

Parameter | Name:

C1096/17 | ECAT: Active error

Data type: UNSIGNED_8

Index: 23479.17

d

=

0x5BB7.0x11

h

• Value "0": No error

• Value "1": An error is active
Display range

(min. value | unit | max. value)

0

1

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1096/18 | ECAT: Activate link messages

Data type: UNSIGNED_8

Index: 23479.18

d

=

0x5BB7.0x12

h

Debug parameter:

If the parameter is set to value "1", all state changes of the slave will be output in the form of a diagnostic frame via

the Ethernet interface. In the event of an error, a wireshark record can be used for error diagnostic purposes.

(»Wireshark«: Program for the analysis of network communication links)

• Value "0": No link messages

• Value "1": Activate link messages
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

;

Read access ; Write access … CINH … PLC STOP … No transfer