Industrial PC | Parameter setting & configuration

Visualisation with »VisiWinNET®«

Constellation and connection

112

L

2.5 EN - 01/2012

How to browse for variable definitions:

1. Click the Add button.

• The Configure device dialog appears.

2. Select the required communication type from the Communication type drop-down

menu:
»VisiWinNET®« and the control system are on the same Engineering PC:
Data manager OPC Tunnel: Access to data of the data manager

(e. g. logbook data),

CAN OPC Tunnel: Access to data of a node on the CAN bus,
SoftPLC OPC Tunnel: Access to variables of the PLC.

»VisiWinNET®« and the control system are on different Engineering PCs:
Remote Data manager OPC Tunnel: Access to data of the data manager

(e. g. logbook data),

Remote CAN OPC Tunnel: Access to data of a node on the CAN bus,
Remote SoftPLC OPC Tunnel: Access to variables of the PLC.
The non-tunnel servers are not relevant for the configuration.

3. Enter the name of the parameter file in the Parameter file text field. The file

extension depends on the device selected:
• OPC server of the PLC: .sym
• OPC CAN bus server and OPC DM server: .eds and .dcf
• Click the ... button to search for a parameter file on a data medium.
• If the CAN OPC tunnel is used, the CAN address and the CAN interface must be

specified.

4. Enter a name in the Device alias text field. This device alias name is a designation

for the device used internally in »VisiWinNET®«.

5. Click the OK button.