Industrial pc | parameter setting & configuration – Lenze PC-based Automation Industrial PC User Manual

Page 169

Advertising
background image

2.5 EN - 01/2012

L

169

Industrial PC | Parameter setting & configuration

Parameter reference

Industrial PC extension modules

C1592

C1593

C1594

C1596

C1598

Parameter | Name:

C1592 | Bus load

Data type: UNSIGNED_32

Index: 22983

d

= 59C7

h

Specification of the average bus load. The bus load is calculated as follows: Bus load = Value in percent x 1000
Display range

(min. value | unit | max. value)

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1593 | Error counter

Data type: UNSIGNED_32

Index: 22982

d

= 59C6

h

Error counter since last initialisation of the CAN interface
Display range

(min. value | unit | max. value)

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1594 | Last error code

Data type: UNSIGNED_32

Index: 22981

d

= 59C5

h

Code of the last error that occurred
Display range

(min. value | unit | max. value)

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596 | CAN node address

Data type: UNSIGNED_8

Index: 22979

d

= 59C3

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

128 63

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1598 | Channel

Data type: UNSIGNED_32

Index: 22977

d

= 59C1

h

Setting range

(min. value | unit | max. value)

Lenze setting
0

;

Read access ; Write access … CINH … PLC STOP … No transfer