Timeout

2000 ... 30000 ms

Timeout for the communication
between QML logger and the
communicator

Options

GPS receiver

Communicator is equipped with GPS

Clear queue on
startup

Clears transmission queue upon
startup

Clear queue if full

Clears transmission queue if it
becomes full

Priority mask lo
Priority mask hi

Priority mask for communications (do
not modify)

Process inbound
messages

QML logger polls and processes
inbound messages as remote
commands

Send responses to
commands

QML logger sends responses to the
inbound commands

Extra op. info to
COM0

Sends extra operation information to
COM0 for troubleshooting

Time
adjustment
tolerance

-1 = disable
1 ... 3600 s

When the current system time differs
from the GPS time more than the
tolerance set with this parameter, the
system time is adjusted to match the
GPS time

Parser
component

2

Empty, <None>, or
Extparser

Parser used to process remote
commands

1. The maximum length of the user data is 229 characters for the globalgram

message type, while with enhanced globalgram recipient the subject and
message body can have 225 characters in total.

2. Visible only in advanced Lizard operation mode.

Table 14

ORBCOMM Communicator Parameters in Lizard