Table 72, Sms configuration parameters – Vaisala Hydromet Data Collection Platform User Manual

Page 333

Advertising
background image

Chapter 5 __________________________________________ Configuring TCP/IP-Based Telemetry

VAISALA______________________________________________________________________ 331

3.

Enter the following parameter values (only the parameters relevant
for SMS configuration are listed):

4.

Click Save to close the settings.

It is also possible to use an external program to execute the sending. In
this case, select Use external command and enter startup command
and parameters for launching the external program to Program
command line
. In this case, neither the modem settings nor Wake-up
message
are used.

Table 72

SMS Configuration Parameters

Parameter

Value

Note

Type

Server socket with
SMS.

Port

Port where the logger is
configured to connect
to.

For more information,
see section

SMS

Handler on page 289

.

GSM Modem
COM port

PC COM port where the
GSM modem is
connected to.

GSM Modem baud rate Baud rate for the GSM

modem.

GSM Modem flow
control

Flow control mode for
the GSM modem.

Telephone number

Telephone number of
the logger’s GSM
modem.

Wake-up message

open <connX>, where
<connX> refers to the
logger SMS handler
configuration

For more information,
see section

SMS

Handler on page 289

.

Optional initialization
commands

Additional initialization
commands for the
modem.

For example,
AT+CPIN="XXXX"
AT+CSCA="<sms
central number>"

NOTE

Connecting to logger with this method can involve significant delays,
depending on how fast the SMS gets through and the logger manages
to establish a GSM connection for IP.