Transmitter Configuration

The configuration parameters of the transmitter are set through the
service terminal with the following command:

CFG <name> <parameter> <value>

A response to the command can be received by giving the command
LASTVAL <name> service. The response can be either

ID set

,

ID

set failed

,

Clock set

, or

Clock set failed

.

After power-up, before any transmissions can be made, the clock must
be set if the transmitter does not have an embedded GPS. The
transmitter ID stored to EEPROM is used after the power-up. If no ID
has been stored, one must be set before any transmissions can be made.

where

CFG

=

Configuration command

name

=

Transmitter name as given in Lizard; for example,
GOES_1

parameter =

Any of the items in the Parameter column in

Table 18

on page 174

value

Any of the items in the Value column in

Table 18 on

page 174

Table 18

Transmitter Configuration Parameters

Parameter

Value

Description

setid

8-character hexadecimal string,
for example, "010012D4"

Sets the ID of the
transmitter without storing
it to EEPROM

setid_eeprom 8-character hexadecimal string,

for example, "010012D4"

Sets the ID of the
transmitter and stores it to
EEPROM

setclock

String including Year, Month,
Day, Hours, minutes, and
seconds in the format
YYMMDDhhmmss

Sets the transmitter clock
(only used for transmitters
without embedded GPS)

Advertising