Figure 148 configuring e-mail message transmission – Vaisala Hydromet Data Collection Platform User Manual

Page 310

Advertising
background image

User's Guide ______________________________________________________________________

308 _________________________________________________________________ M210933EN-C

a.

Link the report to the FTP client by selecting the report in the
Available reports list, the FTP client in the Port/Device list
and then clicking the linking button.

b.

Enter the directory to which reports will be sent.

-

Usually there is a home directory specified for each FTP
user. The directory defined here will be located under that
directory. If the directory does not exist in the server, it
will be created by the QML logger during the first
transmission.

-

This example has the option Use station name set for the
FTP client. The final directory for the reports will be
aws_rep/<station name>, where <station name>
equals the name of the weather station as set in the
MAWS common parameters or by the sname command.

-

Link the DC_Lost_Alert to the SMTP-Client.

-

Enter the e-mail address where message will be sent
to.

-

Select the Use sname@domain as sender option.

0803-104

Figure 148

Configuring E-Mail Message Transmission

10. Add a Create Report alarm to monitor external DC supply, and

connect the report DC_Lost_Alert as Report on activation.