Vaisala Hydromet Data Collection Platform User Manual

Page 331

Advertising
background image

Chapter 5 __________________________________________ Configuring TCP/IP-Based Telemetry

VAISALA______________________________________________________________________ 329

An example configuration for SMS Handler and Virtual COM port used
for service connection is as follows:

1.

Configure the SMS handler to open a connection using VCOM
when SMS with content open conn1 is received.

0906-076

Figure 168

SMS Handler VCOM

2.

Define the remote connection point, that is, IP address and port for
connecting the AWS Client.

Figure 169

Configuring Remote Connection Using Virtual
COM

3.

To enable SMS-triggered service connection using Virtual COM,
the following additional settings must be used:

-

Service connection enabled: Selected

-

Active connection: With any character

Advertising