Appendix A _____________________________________ Configuration Information for Legacy Items

VAISALA______________________________________________________________________ 369

iConnector Configuration

The iConnector can be configured by selecting the device
iConnector_x in the Device configurations view.

0411-095

Figure 198

iConnector Configuration Options

Initialization String

The Initialization string contains the set of parameters that is sent to
iConnector each time the modem is initialized. The default parameters
are listed in

Table 97 on page 369

.

Table 97

Initialization Strings for iConnector

String

Description

AT+iBDRF=a

Autobaud on

AT+iE0

Echo off

AT+iMis=\"at+CGDCONT=1,
\\\"IP\\\",\\\"internet\\\"\"

Initialization string for the GPRS interface
(defines a PDP context)

AT+iATH=2

CHAP authentication

AT+iMTYP=102

Modem type is GSM