Figure 32 – Vaisala Hydromet Data Collection Platform User Manual

Page 77

Advertising
background image

Chapter 3 _____________________________________________ Configuring Modules and Sensors

VAISALA_______________________________________________________________________ 75

To configure the humidity and temperature transmitter, proceed as
follows:

1.

Configure the serial transmission hardware in the Optional
hardware
view as shown in

Figure 32 on page 75

.

In this example, MOD1/1 on RS-232 module DSU232 is selected
for use with the HMT transmitter.

It is recommended that you keep the default settings in the Line
parameters
frame.

0711-139

Figure 32

Optional Hardware View: Configuring Serial
Transmission Hardware for Humidity and
Temperature Transmitter

2.

Proceed to the Equipment view; see

Figure 33 on page 76

.

3.

Scroll down the Available list for HMT330.

4.

Click the Add button to select HMT330.

5.

Double-click the Connector list for HMT330 in the I/O
Connections
frame in order to select the COM port.