Chapter 5 __________________________________________ Configuring TCP/IP-Based Telemetry

VAISALA______________________________________________________________________ 285

Enabling SMS handling does not necessarily require additional
configuration to the modem control. The following settings affect SMS
handling and may be necessary, depending on the planned use.

Table 55

Modem Parameters for SMS Processing

Parameter

Use

Note

SMS centre

Telephone number for the
operator’s SMS center. This is
usually available from the
network
without a fixed setting.
When needed, the number has to
be set using the international
number format. For example,
+3584012345.

To enable this setting,
command exchange
AT_smscentre needs to
be enabled by removing
the disabled selection.
For further instructions,
see section

Command

Exchange Option
Disabled on page 286

.

Answer
incoming

If incoming SMS processing is
required, that is, SMS handler
component is in use, the Answer
incoming
option needs to be
enabled in the modem.

Advertising