Remote Analog Operation

TM-XDOP-01XN

4–7

The analog setpoint and readback pins may be configured to work in either a 0–
5V range or 0–10V range.

The programming lines have their own isolated power source (10mA max), and
this power can be looped back to power the user lines, if required. Connect the
pins as shown in Table 4-3.

Remote Interlock Using a Contact Closure

The interlock input may be configured for use with an external voltage free
contact. Connect pins as shown:

Closing an external contact across the interlock pins B2/A4 will then disable the
unit. Opening the contact will enable the supply output.

Table 4-2 Analog Programming Pins

Pin #

Function

Input/Output

B1

Analog Programming (GND)

Output

B2

12V (unregulated) 10mA max

Output

B3

Voltage Setpoint (0–5/10V)

Input

B4

Current Setpoint (0–5/10V)

Input

B5

Voltage Readback (0–5/10V)

Output

B6

Current Readback (0–5/10V)

Output

Table 4-3 Analog Pin Connections for Power Loop Back

Programming Line Pin #

User Line Pin #

B1

to

A7

B2

to

A6

Table 4-4 Analog Pin Connections with a Contact Closure

Programming Line Pin #

User Line Pin #

B1

to

A5