The input to the power supply requires the following specifications.

AC Line Input Voltage Operating Ranges

Operating Range

nominal 208V

rms

(Standard)

nominal 400V

rms

(with HV-Input option)

190 to 242 V

ac

3

φ (3 wire + safety ground)

342 to 500 V

ac

3

φ (3 wire + safety ground)

Frequency Range

47 to 63 Hz

Maximum Peak In-rush Current at turn on

nominal 208V

rms

(Standard)

nominal 400V

rms

(with HV-Input option)

35 A

rms

(6000 Watt)

70 A

rms

(12000 Watt)

19 A

rms

(6000 Watt)

38 A

rms

(12000 Watt)

Minimum Power Factor

a

nominal 208V

rms

(Standard)

nominal 400V

rms

(with HV-Input option)

a.

At nominal input voltage and maximum power

0.95
0.9

Operating Current

nominal 208V

rms

(Standard)

Maximum

b

Typical

c

b.

At 190V

ac

input voltage, 55

°

C ambient temperature and maximum power

c.

At 208V

ac

input voltage, 25

°

C ambient temperature and maximum power

24 A (6000 Watt)
48 A (12000 Watt)
20 A (6000 Watt)
40 A (12000 Watt)

Operating Current

nominal 400V

rms

(with HV-Input option)

Maximum

d

Typical

e

d.

At 342V

ac

input voltage, 50

°

C ambient temperature and maximum power

e.

At 400V

ac

input voltage, 25

°

C ambient temperature and maximum power

13 A (6000 Watt)
26 A (12000 Watt)
11 A (6000 Watt)
22 A (12000 Watt)