Power Supply Operation

TM-XDOP-01XN

3–27

Configure User Lines

The USER LINES menu option lets you configure the auxiliary status lines

The Auxiliary (Aux) lines are 2 open collector outputs that can be used to monitor
the status of the power supply. The auxiliary lines are referred to as AUX A and
AUX B. See “Making Connections for Remote Control” on page 4–3 for details.
Each user line also has a corresponding annunciator on the front panel display to
indicate when it is on. Aux lines can be set up to report the following status
conditions:

None

Unregul: Output Unregulated

OVP: Over-Voltage Condition

UV: Under-Voltage Condition

OC: Over-Current Condition

UC: Under-Current Condition

OP: Over-Power Condition

UP: Under-Power Condition

AC Off: Input power has failed or is out of range

OTP: Over-Temperature Condition

Hi Temp: High-Temperature Condition

SenseProt: Sense Protection Tripped

Fold Prot: Fold Protection Tripped

CC: Constant Current Mode

CV: Constant Voltage Mode

CP: Constant Power Mode

Out ON: Output On

Out OFF: Output Off