Power Supply Operation

TM-XDOP-01XN

3–25

Table 3-1 Settings Affected by Recall

Feature

Factory Preset Value

Voltage setpoint

0.0V

Current setpoint

0.0A

Power setpoint

103% of power rating

Triggered voltage setpoint

Disabled (DEF)

Triggered current setpoint

Disabled (DEF)

Triggered power setpoint

Disabled (DEF)

Trigger source

None

Low voltage setpoint limit

0.0V

High voltage setpoint limit

103% of voltage rating

Low current setpoint limit

0.0A

High current setpoint limit

103% of current rating

Low power setpoint

0% of power rating

High power setpoint

103% of power rating

Over voltage protection

Disabled (0.0V)

Under voltage protection

Disabled (0.0V) and not shutdown when tripped

Over current protection

Disabled (0.0A) and not shutdown when tripped

Under current protection

Disabled (0.0A) and not shutdown when tripped

Over power protection

Disabled (0.0W) and not shutdown when tripped

Under power protection

Disabled (0.0W) and not shutdown when tripped

Fold shutdown protection

None and delay 0.5s

AC off shutdown recovery

Auto recover

Over temperature
shutdown recovery

Latched

Front panel display config

Show V, I & P

Knob lockout

None

Aux line configuration

None and active low

TM-XDOP-01XN.book Page 25 Monday, July 17, 2006 11:19 AM