Xantrex Technology XDC 20-600 User Manual

Page 202

Advertising
background image

Specifications and Characteristics

A–10

TM-XDOP-01XN

User Line Interface

Includes auxiliary status lines, interlock, and external trigger lines

Switching Frequency

Typical 31 kHz; 62 kHz output ripple

Rise Time

5 to 95% step in output voltage.

Fall Time

For a programmed 95% to 5% step in output voltage.

Time Delay From Power On Until Output Stable

5 s maximum
(Within regulation envelope)

Time Delay From Output Enable Until Output Stable

2 s maximum
(Within regulation envelope)

Output Hold-Up Time – Power Off

Minimum 4 ms (at full load)

Output Hold-Up Time – Source Interruption

Minimum 4 ms with output deviation less than 5% of maximum output voltage
after source interruption.

Maximum Current Sink
Capability, Each Output

10 mA

Maximum Supply Voltage

15 V

dc

Minimum Supply Voltage

4 V

dc

Isolation

300 Vdc with respect to chassis
potential or negative output

Load Condition

Time (Max)

No Load

100 ms

Full Load

100 ms

Load Condition

Time (Max)

No Load

a

a.

Fall time is

≤ 4s for 300 V and 600 V units.

3 s

Full Load

50 ms

TM-XDOP-01XN.book Page 10 Monday, July 17, 2006 11:19 AM

Advertising