To set the Over-Voltage Protection:

The other protection options follow a similar procedure, but have 2 extra steps:

1. When you press PROT SET / ALARMS, the OVP prompt appears. Press

PROT SET/ ALARMS repeatedly to cycle through the other protection
options.

2. Protection options, other than OVP, prompt you with S/D if trip? N

Use the arrow keys to select Yes or No.
Yes shuts down the power supply if the protection limit is reached.
No issues a warning (a message in the Alarms menu) without shutting down
the supply.

These 2 extra steps are shown in the following example.

To set the Under-Voltage Protection:

Step # Do This

You Will See

1

OVP SHUTDOWN

2

OVP SET 0V

3

Use the Voltage knob, the numeric, keypad,
or the arrow keys to enter a value. The value
must be between 0–103% of the unit’s rated
voltage.

OVP SET ####V

4

This setting is saved and the
display returns to its default
operating mode.

PROT SET

ALARMS

ENTER

ENTER

Step # Do This

You Will See

1

OVP SET 0V

2

Press repeatedly until the

desired setting appears.

UVP SET 0V

3

UVP SET 0V

4

Use the Voltage knob, the numeric
keypad, or the arrow keys to enter a
value (0–103% of the unit’s rated
voltage).

UVP SET ####V

5

S/D if trip? N

6

Use the arrow keys to select Yes or No.
For this example, Yes is selected.

S/D if trip? Y

7

This setting is saved and the display
returns to its default operating mode.

PROT SET

ALARMS

PROT SET

ALARMS

ENTER

ENTER

ENTER