Xantrex Technology XDC 20-600 User Manual

Page 123

Advertising
background image

Remote Analog Operation

TM-XDOP-01XN

4–9

Press the LCL/RMT button to begin remote operation via the analog interface.

SCPI

To select which setpoints to control via analog programming lines, use the
command:

SYST:REM:SOUR {AVOL|ACUR|AVC}

Where

AVOL (Analog VOLtage) selects only voltage to be programmed via the
analog programming lines

ACUR (Analog CURrent) selects only current to be programmed via the
analog programming lines

AVC (Analog Voltage and Current) selects voltage and current to be
programmed via the analog programming lines

To select the voltage level:

SYST:COMM:APR:LEV {5|10}

Where

“5” is the 0-5V range, and
“10” is the 0-10V range

To put the unit into remote control:

SYST:REM:STAT REM

Step # Do This

You Will See

1

ERROR MSGS

2

4 times

REMOTE SELECT

3

RS-232

4

or

Select desired option.

Analog V&I,
Analog V, or
Analog I

5

Setting is saved.

MENU



ENTER





ENTER

TM-XDOP-01XN.book Page 9 Monday, July 17, 2006 11:19 AM

Advertising