Output Performance Specifications

TM-XDOP-01XN

A–11

Transient Response Time

1

Time to recover within 0.75% of rated output of previous level after step change
in load current between 50% and 100%.

Mode Crossover

Maximum deviation as a percentage of rated output voltage.

Peak–Peak and RMS Noise Bandwidth Limits

The frequency range for Peak to Peak measurements is 10 Hz–20 MHz.

The frequency range for RMS measurements is 10 Hz–100 kHz.

Maximum Remote Sense Line Drop Compensation

Minimum 3.8 V for each line, 5 V typical

Isolation

1.

Time for the output voltage to recover within 0.75% of rated output of its previous level after a step change
in load current of up to 50% - 100% and 100% to 50% of rated output

Mode

Time

Voltage Mode

3 ms (6000 W models)

Voltage Mode

30 ms (12000 W models)

CV – CC Overshoot

1%

AC Input to Output

1350 V

ac

AC Input to Chassis

1350 V

ac

Output to Chassis

600 V

ac

TM-XDOP-01XN.book Page 11 Monday, July 17, 2006 11:19 AM