Xantrex Technology XDC 20-600 User Manual

Page 75

Advertising
background image

Power Supply Operation

TM-XDOP-01XN

3–13

To set the Over-Power Protection:

To set the Under-Power Protection:

Step # Do This

You Will See

1

OVP SET 0V

2

Press repeatedly until the desired setting

appears.

OPP SET 0W

3

OPP SET 0W

4

Use both the Current and Voltage knobs, or the
numeric keypad, or the arrow keys to enter a value.
The value must be between 0W and 103% of the
unit’s rated power.

OPP SET ####W

5

S/D if trip? N

6

Use the arrow keys to select Yes or No. For this
example, Yes is selected.

S/D if trip? Y

7

This setting is saved and
the display returns to its
default operating mode.

PROT SET

ALARMS

PROT SET

ALARMS

ENTER

ENTER

ENTER

Step # Do This

You Will See

1

OVP SET 0V

2

Press repeatedly until the desired setting

appears.

UPP SET 0W

3

UPP SET 0W

4

Use both the Current and Voltage knobs, or the
numeric keypad, or the arrow keys to enter a value
(must be between 0W and 103% of the unit’s rated
power).

UPP SET ####W

5

S/D if trip? N

6

Use the arrow keys to select Yes or No. For this
example, Yes is selected.

S/D if trip? Y

7

This setting is saved and
the display returns to its
default operating mode.

PROT SET

ALARMS

PROT SET

ALARMS

ENTER

ENTER

ENTER

TM-XDOP-01XN.book Page 13 Monday, July 17, 2006 11:19 AM