Program V,I,P

SCPI

To change setpoints:

SOUR:VOLT <voltage>

SOUR:CURR <current>

SOUR:POW <power>

To check setpoints:

SOUR:VOLT?

SOUR:CURR?

SOUR:POW?

To set a triggered setpoint:

SOUR:VOLT:TRIG <voltage>

SOUR:CURR:TRIG <current>

SOUR:POW:TRIG <power>

See “Triggering Commands” on page 4–36 for more information.

To check a triggered setpoint:

SOUR:VOLT:TRIG?

SOUR:CURR:TRIG?

SOUR:POW:TRIG?

To set limits:

SOUR:VOLT:LIM:HIGH <voltage>

SOUR:VOLT:LIM:LOW <voltage>

SOUR:CURR:LIM:HIGH <current>

SOUR:CURR:LIM:LOW <current>

SOUR:POW:LIM:HIGH <power>

SOUR:POW:LIM:LOW <power>

If the high end of the range was set to 5 volts, the command, SOUR:VOLT 10
would return an error.