SCPI Commands for Digital Interfaces

TM-XDOP-01XN

4–31

Over-Power Protection

To set the Over-Power Protection level:

SOUR:POW:PROT <wattage>

SOUR:POW:PROT:STAT <on-off-state>

The first OPP protection command sets the protection level. The second command
lets you choose a warning alarm only [OFF] or shut down with an alarm [ON] if
the protection level is exceeded.

To check the Over-Power Protection level:

SOUR:POW:PROT?

To check if the Over-Power Protection was tripped:

SOUR:POW:PROT:TRIP?

Under-Power Protection

To set the Under-Power Protection level:

SOUR:POW:PROT:UND <wattage>

SOUR:POW:PROT:UND:STAT <on-off-state>

The first UPP protection command sets the protection level. The second command
lets you choose a warning alarm only [OFF] or shut down with an alarm [ON] if
the protection level is exceeded.

To check the Under-Power Protection level:

SOUR:POW:PROT?

To check if the Under-Power Protection was tripped:

SOUR:POW:PROT:TRIP?

TM-XDOP-01XN.book Page 31 Monday, July 17, 2006 11:19 AM