Remote Operation

4–52

TM-XDOP-01XN

Table 4-15 QUEStionable Status Register

Bit

Bit Weight

Bit Name

Description

0

1

VOLTage Summary

Reflects a summary of the VOLTage Sub-Register.

1

2

CURRent Summary

Reflects a summary of the CURRent Sub-Register.

2

4

TIME Not

implemented

3

8

POWer Summary

Reflects a summary of the POWer Sub-Register.

4

16

TEMPerature Summary

Reflects a summary of the TEMPerature Sub-Register.

5

32

FREQuency Summary

Not implemented

6

64

PHASe Summary

Not implemented

7

128

MODulation Summary

Not implemented

8

256

CALibration

Indicates an error in the unit calibration.

9

512

Not Used

Not implemented

10

1024

Not Used

Not implemented

11

2048

AC Off

Indicates an AC Supply failure.

12

4096

UNRegulated

Indicates that the output is not regulated in either Constant
Voltage mode, Constant Current mode or Constant Power
mode. Reflects the inverse of the Operation Regulation
Summary bit.

13

8192

INSTrument Summary

Not implemented

14

16384

Command Warning

Not implemented

15

32768

Not Used

Always zero

TM-XDOP-01XN.book Page 52 Monday, July 17, 2006 11:19 AM