SCPI Commands for Digital Interfaces

TM-XDOP-01XN

4–47

REGulating Sub-Register

This describes the regulating mode. If none of these bits is active, the output
unregulated (UNRegulated) bit is active in the questionable status register.

SHUTdown Sub-Register

Describes the cause of the power supply shutting down. More than one bit may be
active, and multiple actions will be required to restart the unit. The protection
shutdown sub-register indicates which protection mechanisms have caused the
power supply to shutdown.

Table 4-10 REGulating Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

CV

The power supply is regulating in Constant Voltage mode.

1

2

CC

The power supply is regulating in Constant Current mode.

2

4

CP

The power supply is regulating in Constant Power mode.

Table 4-11 SHUTdown Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

PROTection
Summary

The power supply is shut down by a power supply protection
mechanism.

1

2

INTerlock

The power supply is shut down by INTerlock signal.

2

4

COMMand

The power supply is shut down by a command.

TM-XDOP-01XN.book Page 47 Monday, July 17, 2006 11:19 AM