Temperature sub-register, Standard event status register – Xantrex Technology XDC 20-600 User Manual

Page 168

Advertising
background image

Remote Operation

4–54

TM-XDOP-01XN

TEMPerature Sub-Register

This shows whether the temperature of critical components is near or over the
maximum operating temperature.

Standard Event Status Register

The standard event status register sets bits for specific events during power supply
operation. All bits in the standard event status registers are set through the error
event queue. The register is defined by 488.2 and is controlled using 488.2
common commands, *ESE, *ESE?, and *ESR?.

Figure 4-6, “IEEE 488.2 Status Register and Status Byte” on page 4–54
summarizes the standard Event Status Register.

Table 4-19 TEMPerature Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Over TEMperature

Set if the power supply temperature exceeds the maximum
operating temperature.

1

2

High TEMperature

Set if the power supply temperature exceeds 90% of the
maximum operating temperature.

Figure 4-6 IEEE 488.2 Status Register and Status Byte

Not Used
Not Used
Not Used

MAV

Standard Event Status Register

1

0

3

2

5

4

7

6

Summary of QUESTionable Status

RQS/MSS

Summary of OPERation Status

1

0

3

2

5

4

7

6

9

8

11

10

13

12

15

14

Reserved
Reserved

Reserved
Reserved

Reserved
Reserved

Reserved
Reserved

+

Operation Complete

Query Error

Device Dependent Error

User Request

Power On

Execution Error

Command Error

Not Used

TM-XDOP-01XN.book Page 54 Monday, July 17, 2006 11:19 AM

Advertising