Xantrex Technology XDC 20-600 User Manual

Page 167

Advertising
background image

SCPI Commands for Digital Interfaces

TM-XDOP-01XN

4–53

VOLTage Sub-Register

This shows whether the present voltage level is over or under the specified trip
limit.

CURRent Sub-Register

This shows whether the present current level is over or under the specified trip
limit.

POWer Sub-Register

This shows whether the present power level is over or under the specified trip
limit.

Table 4-16 VOLTage Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Over VOLtage

Set if the supply’s output voltage exceeds the over-voltage trip
level, either user-specified variable trip limit, or the fixed trip
limit.

1

2

Under VOLtage

Set if the supply’s output voltage is less than the user-specified
under-voltage trip level (variable trip limit) and the supply is in
Operation state.

Table 4-17 CURRent Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Over CURrent

Set if the supply’s output current is greater than the user-
specified over-current trip level (variable trip limit) and the
supply is in Operation state.

1

2

Under CURrent

Set if the supply’s output current is less than the user-specified
under current trip level (variable trip limit) and the supply is in
Operation state.

Table 4-18 POWer Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Over POWer

Set if the supply’s output power is greater than the user-
specified over-power trip level (variable trip limit), and the
supply is in Operation state.

1

2

Under POWer

Set if the supply’s output power is less than the user-specified
under-power trip level (variable trip limit), and the supply is in
Operation state.

TM-XDOP-01XN.book Page 53 Monday, July 17, 2006 11:19 AM