Altera Transceiver PHY IP Core User Manual

Page 316

Advertising
background image

Table 12-14: 8B/10B Encoder and Decoder Parameters

Parameter

Range

Description

Enable TX 8B/10B encoder

On/Off

When you turn this option On, the PCS

includes the 8B/10B encoder.

Enable TX 8B/10B disparity control

On/Off

When you turn this option On, the PCS

includes disparity control for the 8B/10B

encoder. Your force the disparity of the 8B/

10B encoder using the

tx_forcedisp

control

signal.

Enable RX 8B/10B decoder

On/Off

When you turn this option On, the PCS

includes the 8B/10B decoder.

Rate Match FIFO

The rate match FIFO compensates for the very small frequency differences between the local system clock

and the RX recovered clock. The following table describes the rate match FIFO parameters.

Table 12-15: Rate Match FIFO Parameters

Parameter

Range

Description

Enable RX rate match FIFO

On/Off

When you turn this option On , the PCS

includes a FIFO to compensate for the very

small frequency differences between the local

system clock and the RX recovered clock.

RX rate match insert/delete +ve

pattern (hex)

User-specified

20 bit pattern

Specifies the +ve (positive) disparity value for

the RX rate match FIFO as a hexadecimal

string.

RX rate match insert/delete -ve pattern

(hex)

User-specified

20 bit pattern

Specifies the -ve (negative) disparity value for

the RX rate match FIFO as a hexadecimal

string.

Enable rx_std_rm_fifo_empty port

On/Off

When you turn this option On, the rate

match FIFO outputs a FIFO empty status flag.

The rate match FIFO compensates for small

clock frequency differences between the

upstream transmitter and the local receiver

clocks by inserting or removing skip (SKP)

symbols or ordered sets from the inter-packet

gap (IPG) or idle stream. This port is only

used for XAUI, GigE, and Serial RapidIO in

double width mode. In double width mode,

the FPGA data width is twice the PCS data

width to allow the fabric to run at half the

PCS frequency.

Enable rx_std_rm_fifo_full port

On/Off

When you turn this option On, the rate

match FIFO outputs a FIFO full status flag.

This port is only used for XAUI, GigE, and

Serial RapidIO in double width mode.

12-18

Standard PCS Parameters for the Native PHY

UG-01080

2015.01.19

Altera Corporation

Stratix V Transceiver Native PHY IP Core

Send Feedback