Mechanical installation – Lenze 8400 User Manual

Page 104

Advertising
background image

Mechanical installation

Standard devices in a power range of 0.25 ... 3 kW

Mounting in ”cold plate” technique

5

104

EDS84ASC552 EN 9.1

Ambient conditions

ƒ

The rated data and the derating factors at increased temperature also apply to the

ambient temperature of the drive controllers.

ƒ

Temperature at the cooling plate of the drive controller: max. 75 °C.

Note!

Apply standard heat-conducting paste or heat-conducting foil onto cooler and

cooling plate before you bolt the controller onto the cooler.

StateLine, HighLine

8400GG105c

Fig. 5-11

Device dimensions

h

b

t

h

1

h

2

b

1

t

1

g

1

g

2

[kW]

[mm]

E84AVxxC2512xX0

0.25

165

102

185

186

226

70

172

6

5

E84AVxxC3712xX0

0.37

E84AVxxC3714xX0

0.37

215

102

163

236

276

70

150

6

5

E84AVxxC551xxX0

0.55

E84AVxxC751xxX0

0.75

E84AVxxC112xxX0

1.1

270

137

163

295

335

70

150

6

5

E84AVxxC152xxX0

1.5

E84AVxxC222xxX0

2.2

E84AVxxC2512xB0

0.25

165

102

205

186

226

70

192

6

5

E84AVxxC3712xB0

0.37

E84AVxxC3714xB0

0.37

215

102

183

236

276

70

170

6

5

E84AVxxC551xxB0

0.55

E84AVxxC751xxB0

0.75

E84AVxxC112xxB0

1.1

270

137

183

295

335

70

170

6

5

E84AVxxC152xxB0

1.5

E84AVxxC222xxB0

2.2