Mechanical installation

Standard devices in a power range of 0.25 ... 3 kW

Filter mounting in ”standard” technique

5

95

EDS84ASC552 EN 9.1

E84ZESR007

Fig. 5-5

Assembly with footprint filter

Proceed as follows for installation:
1. Prepare M5 threaded holes on the mounting plate and equip them with screws and

washers.
– Use four M5 screw and washer assemblies or M5 hexagon socket screws with

washers.

– Do not yet tighten the screws.

2. Mount the filter onto the prepared mounting plate.

– Only tighten the screws hand-tight.

3. Loosen the two screw and washer assemblies to fix the standard device on the filter.

– Two M5 × 14 mm screw and washer assemblies.

4. Mount the standard device onto the filter and tighten the screws.

– Observe the instructions in the documentation for the standard device.
– Tightening torque: 3.4 Nm (30 lb-in)

5. If necessary, preassemble additional units.
6. Align all units.
7. Screw all units onto the mounting plate.

– Tightening torque: 3.4 Nm (30 lb-in)