Electrical installation – Lenze 8400 User Manual
Page 205
Advertising
Electrical installation
Devices in a power range of 30 ... 45 kW (3/PE AC 400 V)
Terminal assignment of the power connections
6
205
EDS84ASC552 EN 9.1
Connection to the DC bus (+U
G
, -U
G
)
Terminal X100
Labelling
Description
+UG
-UG
Alternative connection of the DC-bus voltage
PE
Connection for the PE conductor
8400GG096b
Terminal data
PE
Conductor
cross-section
Tightening
torque
Conductor
cross-section
Tightening
torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
[mm
2
]
[AWG]
[Nm]
[lb-in]
E84AVxxx3034
E84AVxxx3734
E84AVxxx4534
16 ... 50
6 ... 0
4.0
35
Inbus
SW 4
2.5 ... 25
12 ... 2
4.0
35
PZ 2
7 x 1