Technical data, General data and operating conditions – Lenze 8400 User Manual

Page 30

Advertising
background image

Technical data

General data and operating conditions

4

30

EDS84ASC552 EN 9.1

Motor cable length (shielded)

after interference suppression and required earth-leakage circuit breaker

U

rated

P

rated

With LL filter

With SD filter

With LD filter

[V]

[kW]

30 mA FI

30 mA FI

300 mA FI

230

0.25 ... 2.2

 5 m

 25 m

 50 m

400/500

0.37 ... 2.2

-

 25 m

1)

 50 m

1)

400/500

3.0 ... 15

-

 25 m

 50 m

400/500

18.5 ... 45

-

-

 50 m

1)

Observe switching frequency-dependent restrictions according to table ”Motor cable lengths without considering EMC

limit values”

Device-dependent filter assignments: See chapter ”Accessories”, 11.3 and 11.4

If LL filters are used, the fault current  is 3.5 mA. Fixed installation is not required.

Advertising