Braking operation – Lenze 8400 User Manual

Page 261

Advertising
background image

Braking operation

Operation with spring-applied brake

Rated data

8

261

EDS84ASC552 EN 9.1

ƒ

Integrated brake control for devices of the HighLine/TopLine version

Range

Values

Input voltage

DC 24 V in accordance with IEC 61131-2

19.2 ... 28.8 V

Input current

DC 0.1 ... 2.6 A

Output voltage

DC 24 V

Maximum brake current

DC 2.5 A

Internal control

Information on internal brake control is provided in the software manual for the

Inverter Drives 8400 HighLine C / TopLine C.

Maximally connectable

cable cross-section

1.5 mm

2

AWG 16

Further technical data regarding the brake control can be found in chapter

4.7.7.