HighLine C control terminals

Motor holding brake connection

6

236

EDS84ASC552 EN 9.1

6.8.4

Motor holding brake connection

Note!

If terminal X107 is used for connecting a motor holding brake, at least one

basic insulation to the motor or mains potential has to be provided, so that the

protective separation of the control terminals is not limited.

X107

24B

X107

GB

BD1

BD2

"

DC 24 V
(+19.2...+28.8 V)

M

8400HLC037

8400HLC045

Labelling

Description

24B

Connection for external 24 V supply

voltage of the motor holding brake

Observe correct polarity!

DC 19.2 ... 28.8 V, IEC 61131-2

SELV/PELV

Example circuit  258

GB

GND connection for external supply

BD1

Pos. connection of the motor

holding brake (Lenze: WH)

BD2

Neg. connection of the motor

holding brake (Lenze: BN)

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

0.2 ... 1.5

24 ... 16

-

-

-

With wire end ferrule

Advertising