Technical data, Switching frequency-dependent output currents – Lenze 8400 User Manual

Page 59

Advertising
background image

Technical data

Rated data

Operation with increased power at a 400 V mains

4

59

EDS84ASC552 EN 9.1

Switching frequency-dependent output currents

Output currents [A] at switching frequency

2 kHz

4 kHz

8 kHz

16 kHz

Type

I

arated2

I

aM2

I

arated4

I

aM4

I

arated8

I

aM8

I

arated16

I

aM16

E84AVxxx3714

1.6

2.6

1.6

2.6

-

-

-

-

E84AVxxx5514

2.2

3.6

2.2

3.6

-

-

-

-

E84AVxxx7514

2.9

4.8

2.9

4.8

-

-

-

-

E84AVxxx1124

3.8

6.4

3.8

6.4

-

-

-

-

E84AVxxx1524

4.8

7.8

4.8

7.8

-

-

-

-

E84AVxxx2224

6.7

11.2

6.7

11.2

-

-

-

-

E84AVxxx3024xxS

8.8

14.6

8.8

14.6

-

-

-

-

E84AVxxx3024xx0

8.8

14.6

8.8

14.6

-

-

-

-

E84AVxxx4024

11.5

19.0

11.5

19.0

-

-

-

-

E84AVxxx5524

15.6

26.0

15.6

26.0

-

-

-

-

E84AVxxx7524

21.0

33.0

21.0

33.0

-

-

-

-

E84AVxxx1134

28.2

47.0

28.2

47.0

-

-

-

-

E84AVxxx1534

38.4

64.0

38.4

62.4

-

-

-

-

E84AVxxx1834

46.8

78.0

46.8

78.0

-

-

-

-

E84AVxxx2234

56.4

89.3

56.4

89.3

-

-

-

-

E84AVxxx3034

73.2

112.1

73.2

89.3

-

-

-

-

E84AVxxx3734

91.2

136.8

91.2

115.2

-

-

-

-

E84AVxxx4534

107.0

169.1

107.0

146.9

-

-

-

-

I

aNx

Rated value of continuous output current

I

aMx

Maximum output current (overload current)

Periodic load change of 3 s with I

aMx

and recovery time of 12 s according to

the tables under chapter  4.4

Can be obtained in the setting ”x kHz fixed/...” in C00018

Switching

frequency

If the maximum heatsink temperature is reached, the switching frequency is

reduced to 4 kHz.
In the setting ”x kHz var./...” in C00018 the switching frequency is reduced

depending on the output current.
Depending on the switching frequency and e.g. the ambient temperature, it

may be required to reduce the output current (chapter 4.1, operating

conditions).

Advertising
This manual is related to the following products: