Electrical installation – Lenze 8400 User Manual

Page 181

Advertising
background image

Electrical installation

Devices in the power range 0.25 ... 2.2 kW (1/N/PE AC 230 V)

Terminal assignment of the power connections

6

181

EDS84ASC552 EN 9.1

Strip cables

X105

X106

;

;;

;

84MOTL001_a

84MOTL001_b

U, V, W

PE

T1, T2

b

c

e

a

d

f

g

h

[mm]

[mm]

[mm]

E84AVxxx2512

25

65

7

90

9

95

25

10

E84AVxxx3712
E84AVxxx5512

30

65

7

90

9

95

30

10

E84AVxxx7512
E84AVxxx1122

30

65

7

90

9

95

30

10

E84AVxxx1522
E84AVxxx2222

How to proceed:
1. Strip motor cable and cable for motor temperature monitoring according to

specified dimensions.

2. Fold back the shield of the motor cable and motor temperature cable over the cable

sheath. Keep unshielded ends short.

3. Fix shield on the cable sheath (e.g. using a heat-shrinkable tube).
4. Fasten wire end ferrule to PE cable.

– The other cables may be wired without using wire end ferrules.

5. Connect the shields separately to the shield sheet using (metal) cable ties or shield

clamps.
– left: motor cable
– right: cable of motor temperature monitoring
– For strain relief of the cables, measures are required.