Assembly without filter in ”standard” technique
For mounting, use four screws M8 x >16 mm. The mounting location and material must

ensure a durable mechanical connection.

ƒ

Screw and washer assemblies or hexagon socket screws with washers are

recommended..

How to proceed:
1. Prepare the fixing holes on the mounting surface.
2. Screw the controller directly to the mounting surface.

StateLine, HighLine

8400GG108e

Fig. 5-41

Device dimensions

h

b

t

h

1

h

2

t

1

g

1

g

2

g

3

[kW]

[mm]

E84AVxxE3034xXx

30

450

250

250

520

636

237

8.5

16

18

E84AVxxE3734xXx

37

E84AVxxE4534xXx

45

E84AVxxE3034xBx

30

450

250

270

520

636

257

8.5

16

18

E84AVxxE3734xBx

37

E84AVxxE4534xBx